Reading a motor nameplate

What the data on an induction motor nameplate mean — voltage and connection, current, power, speed, power factor, frequency, efficiency class — and which values a drive needs.

Typical nameplate data

FieldExampleMeaning
Voltage / connection400 V Δ / 690 V YSupply voltage for delta / star connection
Current28.5 A / 16.5 ARated current for each connection
Power15 kWMechanical output power at the shaft
Speed1460 rpmRated speed at rated load (slip below 1500 rpm synchronous)
Frequency50 HzSupply frequency for the data above
cos φ0.85Power factor at rated load
Efficiency / class92 % / IE3Efficiency and class per IEC 60034-30-1
DutyS1Continuous duty
Insulation classFWinding temperature limit
IPIP55Protection against dust and water

Useful relations

  • Synchronous speed: n_s = 60 · f / p (p = pole pairs). 1460 rpm at 50 Hz → 4 poles (2 pole pairs), slip ≈ 2.7 %.
  • Electrical input: P_el = √3 · U · I · cos φ — at 400 V, 28.5 A, 0.85: ≈ 16.8 kW; output 15 kW → efficiency ≈ 89 % (nameplate values are rounded).
  • Torque: M = 9550 · P[kW] / n[rpm] → 15 kW at 1460 rpm ≈ 98 Nm.

Star or delta

The winding is designed for one voltage per phase. A motor marked 230 V Δ / 400 V Y is connected in star on a 400 V network; a motor marked 400 V Δ / 690 V Y runs in delta on 400 V (and is suitable for star-delta starting). Wrong connection → overcurrent or weak torque.

What the drive needs

VFDs ask for rated voltage, current, power, frequency, speed and cos φ (sometimes efficiency) for the connection actually used, then measure the motor in the identification run. Wrong nameplate data is one of the most common causes of overcurrent trips and poor speed control.