IgnitionSCADA / visualization software

Server-centric HMI/SCADA platform: a Java gateway with built-in OPC UA server and device drivers (Allen-Bradley, Siemens, Modbus, DNP3 and others), tag historian on SQL databases, alarming, Vision (desktop) and Perspective (web/mobile) clients, gateway network and redundancy; licensed per server, unlimited clients and tags.

Device type
SCADA / visualization software
Official product page
inductiveautomation.com

Documentation · 12

Ignition 8.3 — Alarming

EN

Configuration manual

Alarm configuration on tags, alarm pipelines and notification, journal, shelving and display components.

Official title
Ignition 8.3 — Alarming
Open on manufacturer site online documentation

Link verified 2026-10-04

Ignition 8.3 — Audit log and profiles

EN

Configuration manual

Audit profiles recording user actions such as writes and project changes.

Official title
Ignition 8.3 — Audit log and profiles
Open on manufacturer site online documentation

Link verified 2026-10-04

Ignition 8.3 — Getting started

EN

Getting started

Introducing Ignition, installing and upgrading, modules overview, Perspective vs Vision and the startup guide.

Official title
Ignition 8.3 — Getting started
Open on manufacturer site online documentation

Link verified 2026-10-04

Ignition 8.3 — OPC UA module and device drivers

EN

Communication manual

Built-in OPC UA server and client connections, device connections for PLC drivers and their diagnostics.

Official title
Ignition 8.3 — OPC UA module and device drivers
Open on manufacturer site online documentation

Link verified 2026-10-04

Ignition 8.3 — Perspective module

EN

User manual

Web and mobile HMI: views, components, sessions, bindings and deployment.

Official title
Ignition 8.3 — Perspective module
Open on manufacturer site online documentation

Link verified 2026-10-04

Ignition 8.3 — Redundancy

EN

Configuration manual

Master/backup gateway redundancy, synchronisation, failover behaviour and historian considerations.

Official title
Ignition 8.3 — Redundancy
Open on manufacturer site online documentation

Link verified 2026-10-04

Ignition 8.3 — Scripting

EN

Reference manual

Python (Jython) scripting scopes, event scripts and the system.* functions.

Official title
Ignition 8.3 — Scripting
Open on manufacturer site online documentation

Link verified 2026-10-04

Ignition 8.3 — Security

EN

Configuration manual

User sources, roles, security levels, gateway and project security, SSL/TLS.

Official title
Ignition 8.3 — Security
Open on manufacturer site online documentation

Link verified 2026-10-04

Ignition 8.3 — System architectures

EN

Reference manual

Reference architectures: basic, redundancy, hub-and-spoke, scale-out, edge, IIoT, cloud and security architectures.

Official title
Ignition 8.3 — System architectures
Open on manufacturer site online documentation

Link verified 2026-10-04

Ignition 8.3 — Tag Historian

EN

Configuration manual

Historian providers on SQL databases, storage and partitioning, deadband compression and querying history.

Official title
Ignition 8.3 — Tag Historian
Open on manufacturer site online documentation

Link verified 2026-10-04

Ignition 8.3 — Tags

EN

Configuration manual

Tag providers, OPC/memory/expression/query tags, UDTs, tag properties, quality and events.

Official title
Ignition 8.3 — Tags
Open on manufacturer site online documentation

Link verified 2026-10-04

Ignition 8.3 — Vision module

EN

User manual

Desktop HMI clients: windows, components, templates and client launcher.

Official title
Ignition 8.3 — Vision module
Open on manufacturer site online documentation

Link verified 2026-10-04

Diagnostics · 0

No reviewed diagnostic records for this family yet.

Knowledge · 1

Related tools · 16